Zieus Solutions Pillar Series On-line UPS Photo

Pillar Series Online UPS - 6 KVA to 300 KVA (Three phase Input & Three phase Output)

Provide emergency power back up medical equipment like MRI machines, PET / CT Scan, Operation Theatre Lights among others.


  • 32 bit DSP controlled UPS
  • Inbuilt galvanic isolation
  • Space vector modulation technique
  • 128 x 64 Graphics Display
  • True RMS reading of more than 25 different parameters of UPS
  • Quite operation, low audible noise
  • Superior output quality ; Output voltage distortion < 1%*
  • Unique modular design, offering lowest MTTR
  • Compact system, lowest footprint to kVA ratio in its category
  • High end interfacing options
  • Advance thermal design and monitoring
Capacity
UPS Rating KVA 10kva / 15kva / 20kva / 25kva / 30kva /45kva / 50kva / 60kva / 75kva / 100kva / 125kva/ 150kva
UPS Power KW 8kw / 12kw / 16kw / 20kw / 24kw / 36kw / 40kw / 48kw / 60kw / 80kw / 100kw / 120kw
Input ( Rectifier ) 6pulse Full bridge Rectifier+ Optional Input filter
Nominal AC Input Voltage 3 Phase 380-400-415 V AC + Neutral + Earth
Line Low / High Range >± 20% V AC
Input Frequency Range 50 / 60 ( ±10 Hz )
Input Power factor Up to 0.8 with Option filter @ voltage nominal
Efficient (AC - DC) ≥ 90%
Output (Inverter) PWM Technology with IGBT Based / H bridge. open delta/ star single transformer
Voltage 3 Phase 380 -400-415 VAC + Neutral
Voltage Regulation ± 1%
Frequency (Free running) 50Hz ± 0.1%
Frequency Regulation ± 1%
Phase displacement ± 1.5% for 0 to 100% Unbalanced load
Frequency displacement ± 1.5% for 0 to 100% Unbalanced load
Dynamic stability ± 5% in 2 cycle
Output waveform Pure sine wave
Harmonic Distortion(THD) < 3% (100% Linear Load) / ≤ 5% (100% Non-Linear Load)
Power factor 0.8 Lag to unity
Crest factor 3 : 1
Efficiency (DC-AC) ≥ 90%
Inverter Overload Capacity 105 % Continuous 110 % for 10 Minutes
Isolation Transformer Galvanic Isolation
Manual bypass Available
Battery
Battery type Sealed Maintenance free lead acid, Lead acid Tubular
Battery Rating 12 V DC / 12 AH to 150 AH any rating
Battery Voltage ≥ 360 VDC to 384 VDC
Charger Constant Voltage Constant Current
General
Operating Temperature 0 Deg to 45 Deg. C
Humidity 20% to 95%
Noise Level < 65 dB @ 1 Meter
Indication LED Mains On, Inverter On, UPS On Battery, Load On UPS, Faulty condition, Over Temperature
Audible Alarm Low Battery pre Alarm, Over Load, UPS Over Current
PCU Protection Advanced Electronic protection for input over voltage, under voltage, device safety backed with MCBs, semiconductor fuse, soft start feature for rectifier and PCU converter, battery current limiting protection, built in over load protection, IGBT short circuit protection for rectifier and inverter
Dimension L x W x H - Dimension are in ( mm )
Weight Kg Approximate